All shotcrete construction on projects under DSA jurisdiction requires continuous inspection by an appropriately qualified individual per the California Building Code (CBC). The individual must be DSA certified in shotcrete inspection as required in the 2022 California Building Code.

DSA Shotcrete Special Inspectors shall have a thorough knowledge of the building materials of his or her specialty, shall be able to read and interpret plans and specifications, and must meet other miscellaneous qualification data.

Shotcrete Special Inspectors are listed on the DSA Certified Shotcrete Special Inspector List. Shotcrete Special Inspectors are required to recertify (renew) every four years. Though an individual may be DSA certified; DSA approval is required for each specific project when shotcrete special inspectors are hired independently of a DSA accepted laboratory by a school district.

How to Apply for Shotcrete Special Inspector Certification

  1. A detailed description of the application process is as follows:

    Eligibility

    • Applicants must hold current/valid certification as a Reinforced Concrete Special Inspector through the International Code Council (ICC), as an American Concrete Institute (ACI) Shotcrete Inspector or a state or national organization accepted by DSA.
    • Evidence of at least three years of experience in construction work or special inspection work on one or more projects similar to anticipated work project.

    Apply Online

    Applicants must submit an online Special Inspector application to establish eligibility to take the examination.

    Click Here to apply

    Application Fee: $100

    Application fees are nonrefundable and must be paid at the time of application submission.

    When submitting your application, you must include:

    DSA will review and evaluate each application to verify that the applicant meets the minimum qualification requirements. Upon approval by DSA to sit for the exam, the applicant will receive a detailed admittance letter and exam outline.

    Transition Notice

    Effective February 1, 2026, DSA will no longer accept paper (physical) DSA Form 175 applications. Applicants who have already begun preparing a paper application should submit it prior to this date.

  2. The exam is 60 questions, with a two-hour time limit, and is open book format. Exam references and content are listed on the International Code Council's Exam Catalog webpage for the California state specific DSA Shotcrete Special Inspector exam. Upon passing the exam, DSA will post his/her name on the DSA Certified Shotcrete Special Inspector List.
  3. All DSA certified Shotcrete Special Inspectors must renew their DSA certification every four years prior to expiring. To apply for certification renewal, follow the same steps outlined above with two exceptions: evidence of work history and resubmittal of the DSA 650 is not required.
     
    Upon approval by DSA to sit for the exam, the applicant will receive a detailed admittance letter. Upon passing the exam, DSA will extend the applicant's certification for another four years on the DSA Certified Shotcrete Special Inspector List.
  4. Approval for a project is only required when the Shotcrete Special Inspector contracts individually and directly with the school board or design professional. Application for approval shall be made on form DSA 5-SI. The Shotcrete Inspector shall forward a copy of the completed, signed form to the design professional in responsible charge of the project for his/her signature and submission to DSA for approval. A Shotcrete Special Inspector is not considered approved until such time as his/her completed form bears the signature of the responsible DSA Field Engineer.

    Please note: Shotcrete Special Inspectors employed by the Laboratory of Record (LOR) do not file this form.

    DSA 5-SI: Special Inspector Qualification and Approval (project specific)

    Individuals will be evaluated in accordance with the following criteria prior to approval:

    • Shall be listed on the DSA website as currently certified as a Shotcrete Special Inspector.
    • Shall have met the minimum experience requirements for similar project types.
    • Shall have been approved by the school district, design professional in responsible charge, structural engineer and DSA.