Chapters 23 and 25
Chapter 23 – Wood
Division of the State Architect
2301.1.5 Prohibition
Repealed Cross Laminated Timber (CLT) prohibition in Item 9 since ASCE 7-22 has seismic coefficients incorporated into Table 12.2-1. Clarified that the prohibition by OSHPD in Item 9 is not adopted by DSA.
Office of Statewide Hospital Planning and Development
2308.2 Limitations
Added OSHPD 1R, 2, & 5 banners to applicable requirements in subsections 2308.2.1 through 2308.2.8.
Chapter 25 – Gypsum Board, Gypsum Panel Products and Plaster
Division of the State Architect and
Office of Statewide Hospital Planning and Development
2503.2 Additional requirements for inspection and testing
Amended language in Item 3 to clarify that enforcement agencies are permitted to require tests in accordance with Table 2506.2. No change to regulatory effect.
2507.3 Lath attachment to horizontal wood supports
Added an option to Item 2 to secure overhead lath with a minimum No. 8 wood screw installed with a 1-inch diameter washer.
Repealed the exception to 2507.3 for OSHPD 2 Single-story Type V skilled nursing or intermediate care facilities utilizing wood-frame or light-steel-frame construction.